Hazmat store SolidMaxx CH 2.1
Item number: 274680W
- For the storage of drums and IBCs on a small footprint for access close to production.
- Approved for storage of water-polluting and flammable substances.
- Steel frames and spill pallet are powder coated (RAL 7043, black-grey). The wall elements are made of galvanised profile sheet metal or, in the thermally insulated version, of painted smooth sheet metal panels (RAL 9002, grey-white).
- On request with thermal insulation (50 mm) for walls and roof in mineral wool (ISO A - non-combustible) and heating for frost-free storage.
- Water law tested, one piece 5 mm spill pallet (to density 1.9 g/cm³) with easily removable hot dip galvanised grids (load capacity: 1250 kg/m²).
- When a PE inliner is fitted: galvanised fluid guides all around ensure any leaked substances are safely diverted to the spill pallet.
- Door equipment: 1-wing in narrow version or 2-wing in wide version.
- 100 mm clearance for access underneath using a hand operated electric stacker.
- Natural ventilation provided by weather-protected, all round openings.
- Security lock for protection against unauthorised access.
- Precise roof drainage via the sides (front and back).
- Crane eyes as standard for safe transport to the installation site.
- Optionally with overvoltage protection.
- With natural ventilation with a slit on 3 sides
Structural analysis
The structural calculations for the technical room system are based on Eurocode 3 (EN 1993). The loads on the structure are measured according to Eurocode 1 (EN 1991-1-3) for a characteristic wind load qk,w = 0.585 kN/m² and a ground snow load sk = 2.5 kN/m². The structure is also designed for earthquake zone 3 according to EN 4149, EN 1998-1:2004.
Guidelines for storing flammable liquids (flash point ≤ 60 ° C, classes H226, H225 and H224)
- Observe distance from fire loads (mostly min. 10 m)
- Create equipotential bonding (earthing) (connection point provided); if required provide lightning protection
- Country-specific requirements for air exchange rate
- Specifications in accordance with HSG71
- Specifications in accordance with ATEX Directive 2014/34/EU
Product information
| Technical data | Details |
|---|---|
| Material | Steel |
| Door version | Hinged door |
| Door design | 2 wing doors |
| Door hinge | both sides |
| Containment volume [l] | 1323 |
| Surface | galvanized |
| Dimensions (without attachments) W x D x H [mm] | 2990 x 1890 x 2360 |
| Internal dimensions W x D x H [mm] | 2665 x 1630 x 1830 |
| Colour | Grey white |
| RAL Code | 9002 |
| Secondary colour | Grey |
| RAL Code 2 | 7.043 |
| Overall load capacity [kg] | 4000 |
| Certification / certificate | Dibt (Z-38.5-293) |
| Weight [kg] | 910 |
| Capacity IBC / CP / EP / drum | 2 / 2 / 3 / 8 |
- For the storage of drums and IBCs on a small footprint for access close to production.
- Approved for storage of water-polluting and flammable substances.
- Steel frames and spill pallet are powder coated (RAL 7043, black-grey). The wall elements are made of galvanised profile sheet metal or, in the thermally insulated version, of painted smooth sheet metal panels (RAL 9002, grey-white).
- On request with thermal insulation (50 mm) for walls and roof in mineral wool (ISO A - non-combustible) and heating for frost-free storage.
- Water law tested, one piece 5 mm spill pallet (to density 1.9 g/cm³) with easily removable hot dip galvanised grids (load capacity: 1250 kg/m²).
- When a PE inliner is fitted: galvanised fluid guides all around ensure any leaked substances are safely diverted to the spill pallet.
- Door equipment: 1-wing in narrow version or 2-wing in wide version.
- 100 mm clearance for access underneath using a hand operated electric stacker.
- Natural ventilation provided by weather-protected, all round openings.
- Security lock for protection against unauthorised access.
- Precise roof drainage via the sides (front and back).
- Crane eyes as standard for safe transport to the installation site.
- Optionally with overvoltage protection.
- With natural ventilation with a slit on 3 sides
Structural analysis
The structural calculations for the technical room system are based on Eurocode 3 (EN 1993). The loads on the structure are measured according to Eurocode 1 (EN 1991-1-3) for a characteristic wind load qk,w = 0.585 kN/m² and a ground snow load sk = 2.5 kN/m². The structure is also designed for earthquake zone 3 according to EN 4149, EN 1998-1:2004.
Guidelines for storing flammable liquids (flash point ≤ 60 ° C, classes H226, H225 and H224)
- Observe distance from fire loads (mostly min. 10 m)
- Create equipotential bonding (earthing) (connection point provided); if required provide lightning protection
- Country-specific requirements for air exchange rate
- Specifications in accordance with HSG71
- Specifications in accordance with ATEX Directive 2014/34/EU