AIR EXTRACTION MONITOR EX max 25m³/hr

Item number: 205003W

  • Explosion protected pressure switches for monitoring technical ventilation
  • For notifying a fault in the air extraction system (not in the event of a power cut!)
  • With the new version of HSG71 in 2021, technical ventilation must be equipped with air extraction monitoring (e.g. flow monitors) regardless of the air exchange rate.
  • Differential pressure switch for volume flow control via measurement of differential pressure
  • For gas, mist, vapour and dusts in zones 1, 2, 21, 22 (non-aggressive media)
  • Sensor as piezo pressure transmitter
  • Switching delay to avoid error messages
  • Default setting 120 sec
  • Ex proof in accordance with ATEX II2(1)G Ex emb[ia] IIC T6 / II2(1)D Ex tD [iaD] A21 IP66 T6
  • Audible signal in switch cabinet when the required air extraction volume is not met (not in the event of a power cut)
  • Notice: When sited indoors, the customer must ensure the air extraction is channelled to a safe location outside. After installation of the extraction ducting the pressure conditions will change and the extraction volume flow will need to be set again by the customer. Our Service team would be happy to prepare a quotation for this readjustment operation.
  • Air extraction monitoring for hazardous materials stores up to 25 m²
Full description

New
SALE
bestseller
[[record.name]]
[[record.actionPrice]] [[record.price]] [[record.price]] Excl. VAT
Price on request

New
SALE
bestseller
[[record.name]]
[[record.actionPrice]] [[record.price]] [[record.price]] Excl. VAT
Price on request

Product description

  • Explosion protected pressure switches for monitoring technical ventilation
  • For notifying a fault in the air extraction system (not in the event of a power cut!)
  • With the new version of HSG71 in 2021, technical ventilation must be equipped with air extraction monitoring (e.g. flow monitors) regardless of the air exchange rate.
  • Differential pressure switch for volume flow control via measurement of differential pressure
  • For gas, mist, vapour and dusts in zones 1, 2, 21, 22 (non-aggressive media)
  • Sensor as piezo pressure transmitter
  • Switching delay to avoid error messages
  • Default setting 120 sec
  • Ex proof in accordance with ATEX II2(1)G Ex emb[ia] IIC T6 / II2(1)D Ex tD [iaD] A21 IP66 T6
  • Audible signal in switch cabinet when the required air extraction volume is not met (not in the event of a power cut)
  • Notice: When sited indoors, the customer must ensure the air extraction is channelled to a safe location outside. After installation of the extraction ducting the pressure conditions will change and the extraction volume flow will need to be set again by the customer. Our Service team would be happy to prepare a quotation for this readjustment operation.
  • Air extraction monitoring for hazardous materials stores up to 25 m²

Technical data

Weight [kg] 1,8

Documents

Menu
Log in
Your basketAdded to basket
Go to basket
We would be pleased to provide you with advice!

Give us a call or fill out the form and we will get back to you as soon as possible.

Mon - Thu: 08:30 - 17:00 | Fri: 08:30 - 16:00
i

Calls are handled by our UK team. All sales are processed via our German parent company so are VAT* / tariff free where applicable. *Must be fully IE VAT registered