VARIO-Flow lab workstation GAP Ex 140.090.075
Item number: 274797W
- Ensures the workplace exposure limits (WEL) are safely met when handling chemicals.
- High levels of safety with integral fresh air curtain technology. Air is blown in via rails on the edge of the work surface and the roof, directly into the workplace
- Vapours which are hazardous to health are captured and immediately extracted
- Suitable for all dispensing, adhesive or cleaning tasks using hazardous substances
- Vapours which are hazardous to health are captured and extracted
- Fitted with air supply and extraction monitoring, display, internal lighting and transparent side walls
- Hazardous substance workstation, suitable for installation on workbenches and other workplaces
- Sturdy construction with side sections in 5 mm toughened safety glass, melamine coated rear wall
- Air supply rails for fresh air curtain technology in the floor and head area
- Ready for customer-side connection to an extraction system and 230 V / 50 Hz electrical connection
- Additional fittings such as work surfaces or media connections can be separately selected as options
- Equipment includes base frame and switch cabinet with complete monitoring electronics (must be mounted outside the Ex zone)
- Suitable for all dispensing, adhesive or cleaning tasks using hazardous materials
- With stainless steel work surface (V2A/ 1.4301) as a liquid-tight welded spill tray
Product information
| Technical data | Details |
|---|---|
| Model | GAP Ex 140.090.075 |
| External dimensions W x D x H [mm] | 900 x 750 x 1400 |
| Height with base frame [mm] | 2290 |
| Height, internal [mm] | 1105 |
| Width, internal [mm] | 850 |
| Depth, internal [mm] | 650 |
| Work surface width [mm] | 798 |
| Work surface depth [mm] | 648 |
| Working height [mm] | 890 |
| Weight [kg] | 79 |
| Load capacity [N/m²] | 3000 |
| Number of air extraction connections (items) | 1 |
| Nominal width DN | 250 |
| Volumetric flow rate [m³/h] | 495 |
| Sound level [dB(A)] | 35 |
| Frequency [Hz] | 50 |
| Power consumption, operating [W] | 145 |
| Max. current draw [A] | 1 |
| Recommended air extraction volume [m³/h] | 720 |
| Ex protection class | II 2 G T4 |
| Differential pressure loss per nozzle [Pa] | 140 |
- Ensures the workplace exposure limits (WEL) are safely met when handling chemicals.
- High levels of safety with integral fresh air curtain technology. Air is blown in via rails on the edge of the work surface and the roof, directly into the workplace
- Vapours which are hazardous to health are captured and immediately extracted
- Suitable for all dispensing, adhesive or cleaning tasks using hazardous substances
- Vapours which are hazardous to health are captured and extracted
- Fitted with air supply and extraction monitoring, display, internal lighting and transparent side walls
- Hazardous substance workstation, suitable for installation on workbenches and other workplaces
- Sturdy construction with side sections in 5 mm toughened safety glass, melamine coated rear wall
- Air supply rails for fresh air curtain technology in the floor and head area
- Ready for customer-side connection to an extraction system and 230 V / 50 Hz electrical connection
- Additional fittings such as work surfaces or media connections can be separately selected as options
- Equipment includes base frame and switch cabinet with complete monitoring electronics (must be mounted outside the Ex zone)
- Suitable for all dispensing, adhesive or cleaning tasks using hazardous materials
- With stainless steel work surface (V2A/ 1.4301) as a liquid-tight welded spill tray
-
EU directive -
Suitable for EX zones: yes
Free shipping
to Mainland U.K.
Personal consultation
by our hazmat experts
14-day right of return
in accordance with the terms and conditions
Maintenance and spare parts service
directly from the manufacturer